Deye Battery Setup pages Read!!! | MyBroadband Forum
mybroadband.co.za
@RonSwanson need some info. I see under Deye inverter Battery setting there is a Grid charge tick setting when the battery has reached a selectable Soc setting. Nice to have. See attached pic. Is ...
Deye inverter consumption - Inverters - Power Forum
powerforum.co.za
Good evening, my photovoltaic system has a SUN-6K-SG03LP1-EU deye inverter, with a 14kwh storage system. I noticed that the electricity consumption of the inverter is consistently 250-300W. I think it's too high. What do you think? All my loads are under the UPS output, and if I open the inverter...
Deye - "Zero Export To CT" Reduces Power & Load Values
powerforum.co.za
Deye downgraded my software by one version for me because the latest that I was on would default to Zero Export to CT. I was then able to select Zero Export to Load and my weird negative values went away. I can only imagine that my CTs, besides being uneccessary, were installed incorrectly throwing the values off.
Deye 12K Single Phase Showing UPS-Load when there isn't one.
diysolarforum.com
Hi All, Just setup Deye 12K SUN-12K-SG02LP1-EU-AM3 single phase inverter but am getting a strange reading in the monitoring section, I Have Production, Grid, Battery, Load as expected, but I also have something called UPS-Load which is showing as being fed power. I only have a connection into...
SOLARMAN / Sunsync Connect / Deye Stick Logger are garbage
diysolarforum.com
With Deye's stick logger, all you can do is login to it for the sole purpose of configuring it to connect to your home WiFi, so that DEYE engineers and other 3rd party software can access, login, and manage, and collect information from your inverter. You, on the other hand, don't get direct access.
Something strange in app DEYE CLOUD - DIY Solar Power Forum
diysolarforum.com
The Deye states - 100% unbalanced and up to 50% of rated power for single phase. In our case with DEYE SUN-15K-SG01HP3-EU-AM2, this means in on-grid mode we have up to 7.5kW on some phase (and up to 7.5 for both together), correct? What about the offgrid mode, when the battery is attached and release power via LOAD port of inverter?
Deye Inverter Issues. - DIY Solar Power Forum
diysolarforum.com
I have the exact same problem with the Solarman and Deye Cloud apps with my 12 kW hybrid Deye. The solar and battery power report correctly, but the grid and load power are off by exactly a factor of ten. The Deye inverter is showing the correct values, but the apps are reporting a factor of 10 too low.
Deye Battery Settings Questions - Inverters - Power Forum - Renewable ...
powerforum.co.za
Selecting “Lithium” for Batt Mode is mutually exclusive with “Use Batt V” and “Use Batt %” so presumably % is used for other settings? What other battery settings apply when Batt Mode is Lithium? For example are the setting for Float, Absorption, and Equalization ignored? The BMS has a voltage se...